■ Friendly user interface; MFD (multi-function display)
■ 3 Steps charging
■ Overload and short-circuit protection
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Set utility priority/ Battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 100/110/120; frequency can be set to 50/60Hz
■ Set utility charging on/off switch
■ Built-in 80A MPPT charger
■ Acid or Lithium Select
■ WiFi port (optional)
■ With BMS lithium battery communication function (CAN port)
MODEL | PV33-1012 TLV | PV33-1512 TLV | PV33-1524 TLV | PV33-2012 TLV | PV33-2024 TLV | PV33-3024 TLV | PV33-3048 TLV | PV33-4024 TLV | PV33-4048 TLV | PV33-5048 TLV | PV33-6048 TLV | |
INVERTER OUTPUT | ||||||||||||
Rated power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
Power factor | 1 | |||||||||||
Wave form | Pure sine wave | |||||||||||
Output voltage RMS | 100V / 110V / 120VAC (200V / 220V / 240VAC) ±10% | |||||||||||
Output frequency | 50Hz or 60Hz (±0.3Hz) | |||||||||||
Inverter efficiency (peak) | >85% | |||||||||||
Line mode efficiency | >95% | |||||||||||
Overload | 100%<Load<110% (alarm 5min then stop outputand fault code 07) 110%<Load<125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | |||||||||||
Surge rating | 3000VA | 4500VA | 6000VA | 9000VA | 12000VA | 15000VA | 18000VA | |||||
Capable of starting electric motor | 1P | 1P | 1.5P | 1.5P | 2P | 3P | ||||||
BATTERY | ||||||||||||
Battery voltage | 12VDC/24VDC | 24VDC/48VDC | 48VDC | |||||||||
Minimum start voltage | 10V/ 10.5V/ 11V/ 11.5V/ 12V±0.5V; 12VDC×2 for 24V; ×4 for 48VAC | |||||||||||
Low battery cut off | low voltage fault code 04
(10V/ 10.5V/ 11V/ 11.5V/ 12V) for 12V model (21V/21V /22V/ 23V/ 24V) for 24V model (40V/ 42V/ 44V/ 46V/ 48V) for 48V model |
|||||||||||
Low battery alarm | Add 0.5/battery: (low battery alarm one second one time) (10V/ 10.5V/ 11V/ 11.5V/ 12V) +0.5VDC for 12V model
(21V/ 21V/ 22V/ 23V/ 24V) +1VDC for 24V model (40V/ 42V/ 44V/ 46V/ 48V) +2VDC for 48V model |
|||||||||||
High voltage alarm | Add +1V/battery: (high voltage one second one time / after 30s fault 03) (12-14.5V) +1VDC for 12V model
(24-29V) +2VDC for 24V model (48-58V) +4VDC for 48V model |
|||||||||||
Save mode | Load ≤40W(110V) / 80W(220V) | |||||||||||
AC INPUT MODE | ||||||||||||
Input waveform | Pure sine wave | |||||||||||
Nominal input voltage | 200Vac / 220Vac / 240Vac | |||||||||||
Max input voltage | 270Vac MAX | |||||||||||
Input frequency | 50Hz / 60Hz (auto sensing) | |||||||||||
Efficiency (AC mode) | >95% (load, full battery) | |||||||||||
Transfer time AC to DC | 15ms(typical) | |||||||||||
SOLAR CHARGER | ||||||||||||
Maximum PV Array Power | 1250W | 1250W | 2500W | 1250W | 2500W | 2500W | 5000W | 2500W | 5000W | 5000W | 5000W | |
Maximum PV Charge Current | 80A±4A | |||||||||||
DC Voltage | 12V / 24V | 24V / 48V | 24V / 48V | |||||||||
MPPT Range @ Operating Voltage | 15~95VDC @ 12V / 30~230VDC @ 24V | 30~230VDC @ 24V / 60~230VDC @48V | 60~230VDC @48V | |||||||||
Maximum Solar Input Voltage | 100±2Vdc / 245±2Vdc | 245±2Vdc | 245±2Vdc | |||||||||
Maximum Efficiency | >98% | |||||||||||
Standby Power Consumption | <2W | |||||||||||
CHARGE MODE | ||||||||||||
Max charge current (±5A) | 12V | 30A | 45A | 60A | / | / | / | / | ||||
24V | 20A | 25A | 30A | 40A | 60A | / | / | |||||
48V | / | / | / | 20A | 30A | 35A | 40A | |||||
Min charge current 10A. Change by every 5A | ||||||||||||
DIMENSIONS | ||||||||||||
Machine Dimension (W*H*D) | 443*359.2*188mm | 544*362*188mm | ||||||||||
Package Dimension (W*H*D) | 598*457*308mm | 698*457*308mm | ||||||||||
Warranty | 1year |