■ 3 Steps charging
■ MFD (multi-function display)
■ Overload and short-circuit protection
■ Set charging voltage/charging current.
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority/ Battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 110V/115V/120V
■ Inverter frequency can be set to 50/60Hz
■ Set utility charging on/off switch
■ Acid or Lithium Select
■ WIFI monitoring function (optional)
■ With BMS lithium battery communication function (CAN port)
MODEL | EP30-1012 LV2 | EP30-1024 LV2 | EP30-1512 LV2 | EP30-1524 LV2 | EP30-2012 LV2 | EP30-2024 LV2 | EP30-3024 LV2 | EP30-3048 LV2 |
Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | 48VDC |
INVERTER OUTPUT | ||||||||
Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | ||||
Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | ||||
Capable Of Starting Electric Motor | 1HP | 2HP | ||||||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||
Nominal Output Voltage RMS | 110V/115V/120VAC ±10% (RMS) | |||||||
Output Frequency | 50Hz / 60Hz±0.3 Hz | |||||||
Inverter Efficiency(Peak) | >88% | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 1.0 | |||||||
Typical Transfer Time | 10ms(max) | |||||||
Overload | 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07) | |||||||
AC INPUT | ||||||||
Voltage | 120VAC | |||||||
Selectable Voltage Range | 75~135VAC(For Personal Computers) | |||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||
BATTERY | ||||||||
Minimum Start Voltage | (10V/ 10.5V/ 11V/ 11.5V/ 12V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Alarm | (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Cut off | 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Voltage Alarm | (12-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Battery Voltage Recover | (12-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Idle Consumption-Search Mode | Load ≤50±20W(120V) | |||||||
CHARGER | ||||||||
Output Voltage | Depends on battery type | |||||||
Charger AC Input Breaker Rating | 1K/30A | 3K/40A | ||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode, *4 for 48VDC mode) | |||||||
Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | 20A |
BYPASS & PROTECTION | ||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
AC Input Breaker | 30A | 40A | ||||||
MECHANICAL SPECIFICATIONS | ||||||||
Mounting | Wall Mount | |||||||
Machine Dimension (W*H*D) | 493*303*200mm | |||||||
Package Dimension (W*H*D) | 615*400*319mm | |||||||
OTHER | ||||||||
Operation Temperature Range | 0°C to 40°C | |||||||
Storage Temperature | -15°C to 60°C | |||||||
Audible Noise | 60dB MAX | |||||||
Display | LED+LCD | |||||||
Standard Warranty | 1 year |