■ Sine wave inverter
■ Adjustable charging current from utility
■ Adjustable battery charging current
■ 3 steps charging algorithm
■ Friendly user interface
■ Multi-function display
■ Overload and short-circuit protection
■ Battery reverse polarity protection
■ Deep discharge protection
■ Automatic voltage regulationCommunication with PC
MODEL | EH29-0312 LV | EH29-0412 LV | EH29-0512 LV | EH29-0612 LV | EH29-0812 LV | EH29-1012 LV |
Default Battery System Voltage | 12VDC | |||||
INVERTER OUTPUT | ||||||
Rated Power | 300W | 400W | 500W | 600W | 800W | 1000W |
Surge Rating | 900VA | 1200VA | 1500VA | 1800VA | 2400VA | 3000VA |
Waveform | Pure sine wave | |||||
Voltage Regulation | Battery mode: 110 or 120VAC Line mode: 95~125VAC | |||||
Output Frequency | 50Hz / 60Hz | |||||
Invertert Frequency (Peak) | >75% | |||||
Bypass Efficiency | >95% | |||||
Output Transfer Time | 8ms(typical) 12ms(max) | |||||
AC INPUT | ||||||
Voltage | 110/120VAC | |||||
Selectable Voltage Range | 70~140VAC ±5% | |||||
Low Battery Alarm | 70VAC ±5% | |||||
Low Voltage Recover | 75VAC ±5% | |||||
High Battery Alarm | 140VAC ±5% | |||||
High Voltage Recover | 135VAC ±5% | |||||
Low Frequency Alarm | 45 ±5Hz | |||||
Low Frequency Recover | 46 ±5Hz | |||||
High Frequency Alarm | 65 ±5Hz | |||||
High Frequncy Recover | 64 ±5Hz | |||||
Nominal Input Range | 50Hz / 60Hz ±5Hz | |||||
AC Auto Restart | YES | |||||
BATTERY | ||||||
Minimum Start Voltage | Low Battery Voltage Cutoff+0.5V | |||||
Low Battery Alarm | Low Battery Voltage Cutoff+0.5V | |||||
Min battery voltage for power on | Shutdown voltage +0.5V | |||||
Low Battery Cutoff | 10-12.0VDC | |||||
High Battery Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC) | |||||
AC CHARGE | ||||||
Floating Voltage | 13.5-14.5VDC | |||||
Boost Voltage | 13.8~14.5VDC | |||||
Maximum Charge Current | 300W | 400W | 500W | 600W | 800W | 1000W |
10A | 10A | 15A | 20A | 25A | 30A | |
BYPASS & PROTECTION | ||||||
Input Waveform | Pure sine wave | |||||
Input Frequency | 50Hz or 60Hz | |||||
Overload Protection | >110%~125% Load foult affter 60s; >125%~150% Load foult affter 3s; >150% Load fault after 500ms | |||||
Over Temperature Protection | ≥90℃ | |||||
Bypass Output Protection | 15A 250VAC | |||||
Output Circuit Protection | YES | |||||
Battery Reverse Protection | Optional | |||||
Battery Low Voltage Protection | YES | |||||
Battery High Voltage Protection | YES | |||||
Bypass Breaker Rating | 15A | |||||
Maximum Bypass Current | 15A | |||||
MECHANICAL SPECIFICATION | ||||||
Machine Dimension (W*H*D) | 319*300.5*132.2mm | |||||
Package Dimension (W*H*D) | 391*325*187mm | |||||
Operating Temperature | 0℃ ~40℃ 0~90% relative humidity (non-condensing) | |||||
Storage Temperature | -15℃ to 55℃ | |||||
Altitude | ≤1000M | |||||
Audible Noise | ≤60dB | |||||
Display | LED+LCD | |||||
Cooling Mode | Fan cooling | |||||
Fan Starting | >45℃ starting, <30℃ Closing | |||||
Communication | USB | |||||
CERTIFICATION & STANDARDS | ||||||
CE-LVD (EN IEC62109-1:2010,EN IEC62109-2:2011)
CE-EMC+LVD (EN6100-6-4:2007, EN6100-6-2:2005+EN IEC62109-1:2010, EN IEC62109-2:2011) IEC60950-1:2005A+1:2009+A2:2013 EN IEC62040-1:2019 |
MODEL | EH29-0624 LV | EH29-0824 LV | EH29-1024 LV |
Default Battery System Voltage | 24VDC | ||
INVERTER OUTPUT | |||
Rated Power | 600W | 800W | 1000W |
Surge Rating | 1800VA | 2400VA | 3000VA |
Waveform | Pure sine wave | ||
Voltage Regulation | Battery mode: 110 or 120VAC Line mode: 95~125VAC | ||
Output Frequency | 50Hz / 60Hz | ||
Invertert Frequency (Peak) | >81% | ||
Bypass Efficiency | >95% | ||
Output Transfer Time | 8ms(typical) 12ms(max) | ||
AC INPUT | |||
Voltage | 110/120VAC | ||
Selectable Voltage Range | 70~140VAC ±5% | ||
Low Battery Alarm | 70VAC ±5% | ||
Low Voltage Recover | 75VAC ±5% | ||
High Battery Alarm | 140VAC ±5% | ||
High Voltage Recover | 135VAC ±5% | ||
Low Frequency Alarm | 45 ±5Hz | ||
Low Frequency Recover | 46 ±5Hz | ||
High Frequency Alarm | 65 ±5Hz | ||
High Frequncy Recover | 64 ±5Hz | ||
Nominal Input Range | 50Hz / 60Hz ±5Hz | ||
AC Auto Restart | YES | ||
BATTERY | |||
Minimum Start Voltage | Low Battery Voltage Cutoff+0.5V | ||
Low Battery Alarm | Low Battery Voltage Cutoff+1.0V | ||
Min battery voltage for power on | Shutdown voltage +1V | ||
Low Battery Cutoff | 20.0-24.0VDC | ||
High Battery Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC) | ||
AC CHARGE | |||
Floating Voltage | 27-29VDC | ||
Boost Voltage | 27.6~29VDC | ||
Maximum Charge Current | 600W | 800W | 1000W |
10A | 15A | 15A | |
BYPASS & PROTECTION | |||
Input Waveform | Pure sine wave | ||
Input Frequency | 50Hz or 60Hz | ||
Overload Protection | >110%~125% Load foult affter 60s; >125%~150% Load foult affter 3s; >150% Load fault after 500ms | ||
Over Temperature Protection | ≥90℃ | ||
Bypass Output Protection | 15A 250VAC | ||
Output Circuit Protection | YES | ||
Battery Reverse Protection | Optional | ||
Battery Low Voltage Protection | YES | ||
Battery High Voltage Protection | YES | ||
Bypass Breaker Rating | 15A | ||
Maximum Bypass Current | 15A | ||
MECHANICAL SPECIFICATION | |||
Machine Dimension (W*H*D) | 319*300.5*132.2mm | ||
Package Dimension (W*H*D) | 391*325*187mm | ||
Operating Temperature | 0℃ ~40℃ 0~90% relative humidity (non-condensing) | ||
Storage Temperature | -15℃ to 55℃ | ||
Altitude | ≤1000M | ||
Audible Noise | ≤60dB | ||
Display | LED+LCD | ||
Cooling Mode | Fan cooling | ||
Fan Starting | >45℃ starting, <30℃ Closing | ||
Communication | USB | ||
CERTIFICATION & STANDARDS | |||
CE-LVD (EN IEC62109-1:2010,EN IEC62109-2:2011)